Ngingakwazi Ukuhlanganisa Amabhethri Amadala Namasha e-UPS?

Ngingakwazi Ukuhlanganisa Amabhethri Amadala Namasha e-UPS?

Ekusetshenzisweni kwe-UPS namabhethri, abantu kufanele baqonde ezinye izinyathelo zokuphepha.Umhleli olandelayo uzochaza ngokuningiliziwe ukuthi kungani amabhethri e-UPS ahlukene amadala engakwazi ukuxutshwa.

⒈Kungani amabhethri e-UPS amadala namasha amaqoqo ahlukene engasetshenziswa ndawonye?

Ngenxa yokuthi amabhethri ahlukene, amamodeli, namabhethri e-UPS amasha namadala anokumelana okuhlukile kwangaphakathi, amabhethri anjalo e-UPS anomehluko ekushajweni nasekushajweni.Uma isetshenziswa ndawonye, ​​ibhethri elilodwa lizoshajwa kakhulu noma lishajwe kancane futhi elamanje lizohluka, okuzothinta i-UPS yonke.ukusebenza okuvamile kwesistimu yokuphakela amandla.

Hhayi ochungechungeni noma ngokufana.

1. Ukushajwa: Kumabhethri anamandla ahlukene, lapho eshajwa, elilodwa lawo lizokhishwa kuqala, kuyilapho elinye lisenogesi ophakeme.

2. Ibhethri ifile: isikhathi sokuphila sifinyezwa ngo-80%, noma sonakalisiwe.

3. Ukushaja: Uma ushaja amabhethri anamandla ahlukene, elilodwa lawo lizoshajwa ngokugcwele kuqala, kuyilapho elinye lisenamandla ombane aphansi.Ngalesi sikhathi, ishaja izoqhubeka nokushaja, futhi kunobungozi bokushaja ibhethri eligcwaliswe ngokugcwele.

4. Ukushajwa kwebhethri ngokweqile: Kuzophula ibhalansi yamakhemikhali, futhi nge-electrolysis yamanzi, kuzolimaza nebhethri.

⒉Iyini i-voltage yokushaja entantayo yebhethri le-UPS?

Okokuqala, ukushaja okuntantayo kuyindlela yokushaja yebhethri le-UPS, okungukuthi, lapho ibhethri selishajwe ngokugcwele, ishaja isazohlinzeka nge-voltage engaguquki kanye neyamanje ukuze ibhalansise ukuphuma kwebhethri ngokwayo futhi iqinisekise ukuthi ibhethri lingakwazi ukushaja. ishajwe ngokugcwele isikhathi eside.I-voltage kuleli cala ibizwa ngokuthi i-float voltage.

⒊.Hlobo luni lwendawo okufanele ibhethri le-UPS lifakwe kuyo?

⑴Ukungena komoya kuhle, okokusebenza kuhlanzekile, futhi nezikhala azinazo izithiyo.Qinisekisa ukuthi kuneshaneli ebanzi okungenani engu-1000 mm ngaphambili kwezinto zokusebenza ukuze ufinyeleleke kalula, kanye nesikhala okungenani esingu-400 mm ngaphezu kwekhabhinethi ukuze kungene umoya kalula.

⑵Idivayisi nendawo ezungezile ihlanzekile, icocekile, ayinadoti futhi ayijwayele ukuba nothuli.

⑶Akufanele kube khona igesi ebolayo noma ene-asidi eduze kwedivayisi.

⑷ Ukukhanyisa kwangaphakathi kwanele, i-insulating mat iphelele futhi inhle, izinto ezidingekayo zokuphepha nemishini yokucisha umlilo iphelele, futhi indawo ilungile.

⑸Izinga lokushisa lomoya ongena ku-UPS akufanele lidlule ku-35°C.

⑹ Izikrini namakhabethe kufanele kuhlanzeke futhi kungabi nothuli nama-sundries.Kwenqatshelwe ngokuphelele ukugcina izinto ezivuthayo neziqhumayo.

⑺Alukho uthuli oluqhumayo noluqhumayo, alukho igesi ebolayo nevikelayo.

⑧Akukho ukudlidliza okuqinile nokushaqeka endaweni yokusetshenziswa.

 